  Special topics on transformer dielectric loss tester  
     
Release time:2016-03-20 14:23:24 Source:Great electrical equipment Co., Ltd.Number of reading:801次
 

A measurement of dielectric loss tangent of TG what is the significance?

Dielectric loss tangent of dielectric loss and dielectric loss factor or. Measurement of dielectric loss factor is a very high sensitivity test project, it can be found that the insulation of power equipment as a whole is affected by moisture, deterioration of mass and small volume of test equipment through and not through the local defect. For example: the casing of a transformer, the normal TG value is 0.5%, and when the TG value is 3.5%, 7 times the difference between the two data, and the measurement of insulation resistance, moisture before and after the numerical difference is not.

The measurement of dielectric loss factor has high sensitivity to the reflection of the defects, so it has been widely used in electrical equipment manufacturing and power equipment handover and preventive test. Transformer, generator, circuit breakers and other electrical equipment, the dielectric loss test "procedures" have been made.

Two. The current status and technical difficulties of the current domestic dielectric loss tester?

Dielectric loss tester technology develops very quickly, is widely used in power system before QS1 Schering bridge is being instead of intelligent type of dielectric loss tester, a new generation of dielectric loss tester are built-in boost device and a standard capacitor, and has simple operation, accurate data, test result is read convenient wait for a characteristic. Although the current dielectric loss test technology has developed rapidly, but compared with the international level, there is still a big gap in many aspects, the gap is mainly reflected in the following aspects:

(1) anti interference ability

Due to the dielectric loss measurement is a high sensitivity, so the test data also easily interfered by external electric field, taken in the dielectric loss tester anti-interference methods mainly include: phase inversion method, phase shifting method, different frequency method. Although these methods can solve the problem of interference to a certain extent, but when the external disturbance is strong, it will still have a large deviation.

(2) the test accuracy of reverse connection

Site a lot of power equipment have been ground. Therefore, it is necessary to use reverse connection method were detected, but reverse connection, there are many factors that influence the testing data often data will have a large bias, especially when subjects product capacity of smaller, such as casing, a high-voltage wire mopping the floor test (some dielectric loss tester with high-voltage wire although mopping the floor use, but the leakage current) is large, will seriously affect the test accuracy.

Three. What is the "full automatic anti interference source", compared with the other kinds of anti-jamming methods have the characteristics of what?

So-called "full automatic anti interference source, namely inside the instrument has a set of detection device, can detect the amplitude and phase of the interference signals, transmits information related to the CPU, the CPU output commands to the" anti interference source control device, the device will be in the interior of the instruments produce a and dry disturbance signal amplitude identical but opposite to the phase of the "anti interference signal and interference signal superposition offset to achieve anti-jamming. Due to the whole test process, the "anti interference source" automatically generated, the user does not need to intervene, we call the "full automatic anti interference source" ".

Four. Traditional anti-interference methods include phase inversion method, phase shifting method, measuring method, the working principle of how to?

1, reverse phase method

The instrument working power supply is positive and inverse two times of reverse phase test, the two test results are analyzed and processed to achieve the purpose of anti interference, the method has a certain effect in the case of weak external interference.

2, phase shift method

Ideas due to the phase inversion method ", but the working power supply of the inverted phase change is to the phase shifting interference signal are the same and to reduce the influence of interference. The practice shows that under the strong interference, the data is still a big deviation.

3, different frequency method

This is a method developed in recent years. Its basic principle is the working power supply frequency is 50Hz, namely with the frequency of different, so that the sampled signal of two different frequency signal (test current and interference current superimposed, through the analog filter and digital filter for signal filtering, attenuation frequency signal, in order to achieve the purpose of anti-interference. The practice shows that the method of anti-interference ability is better than the "reverse phase method" and "phase shift", but in certain circumstances, due to the influence of interference data still have deviation, and even negative. In addition, because of its own characteristics, there are several aspects of the contradiction:

(1) the choice of frequency: the closer the frequency and frequency, the weaker the ability to resist interference, but the better the equivalent; frequency and power frequency, the stronger the ability to resist interference, but the less effective.

(2) in order to enhance the equivalence, some instruments use a "double frequency", you can choose two kinds of frequency test, such as 60Hz and 40Hz, but the problem is not consistent with the results of the two frequency test how to do? For simple average processing power and power frequency equivalent?

(3) the analog filter has the phase shift problem, the fixed phase shift can be compensated by the computer, but when the temperature and other conditions change caused by the phase shift characteristic changes, it will seriously affect the test results of the dielectric loss value.

 
主站蜘蛛池模板: 国产午夜男女爽爽爽爽爽 | 麻豆国产av无码精品一区二区 | 欧美日韩一区二区三区在线观看电影 | 91在线无码视频 | 亚洲v欧美v日韩v在线观看 | 麻豆精品国产自产在线观看一 | 91人人妻人人做人人爽男同 | 亚洲日本在线中文字幕 | 91精品啪在线观看国产优客传媒 | 免费级毛片无码下 | 三上悠亚av作品在线观看 | 亚洲av成人影片在线观看 | 国产尤物在线视精品在亚洲 | 亚洲精品中文字幕久久久久 | 蜜桃97迅雷下载 | 天堂无码久久综合东京热 | a级情欲片在线观看 | 成人永久免费 | 亚洲av无码国产精品色午 | 毛片一级片电影高清完整版免费在线观看 | 免费无码又爽又刺激高潮的视频 | 国产精品巨作av无 | 国产精品中文原创av巨作首播 | 一色屋精品视频 | 亚洲精品一级毛片在线播放 | 片在线观看精品 | 日韩好片一区二区在线看 | 国产99视频精品免费专区 | 日本少妇高潮喷水xxxxxxx | 91香蕉亚洲 | 91久久久精品无码一区二 | 免费a级毛片无码a | 国产黄页视频在线观看 | 亚洲v欧美v日韩v在线观看 | 国产成人精品视频在放 | 尤物国产精品福利三区 | 狠狠色综合网久久久久久 | 字幕久久网站 | 午夜福利亚洲精品久久 | 夜夜草官 | 国产精品爆乳在线播放不卡 |